WHEN
DISASTER STRIKES-WE DELIVER
SOLUTIONS
Water Damage Restoration Procedures
Select Restorations main goal after
any water damage situation, Is to
return the structure back to a
pre-loss conditions as quickly as
possible without causing any
unnecessary or additional damage.
Select Restoration uses only state
of the art equipment to dry your
affected areas more efficiently
enabling us to do more restoring and
less replacing. Our fast turnaround
time provides insurance companies
quicker claim closings, lower claim
costs and higher customer
satisfaction. Select Restoration
remains at the forefront of the
water restoration industry by
utilizing the latest and up to date
drying equipment and techniques.
Select Restoration has the equipment
needed to get the job done Right!!!!
FLIR THERMAL
IMAGINE INFRARED CAMERAS CAN DETECT
WATER DAMAGE


Above: A dry closet? Look again -
moisture (seen in purple) still
remains trapped in the wall
unseen...
What Is
Thermal Imaging Infrared Technology?
SEE WHAT
THE NAKED EYE CAN'T. GET TRUE
ASSESSMENT
Thermography is
the use of an infrared imaging and
measurement camera to "see" and
"measure" thermal energy emitted
from an object. Thermal, or infrared
energy, is light that is not visible
because its wavelength is too long
to be detected by the human eye;
it's the part of the electromagnetic
spectrum that we perceive as heat.
Unlike visible light, in the
infrared world, everything with a
temperature above absolute zero
emits heat. Even very cold objects,
like ice cubes, emit infrared. The
higher the object's temperature, the
greater the IR radiation emitted.
Infrared allows us to see what our
eyes cannot. Infrared thermography
cameras help us determine what can
stay and what wet material has to
come out. This insures we only take
out the damaged material! Most
companies tell you it's wet to be
able to remove more materials and
BILL FOR MORE DAMAGE! With this
Thermal Imaging Technology There is
no guessing. DON'T GET BURNED BY
CHEATING CONTRATORS!
|
|
|
|
|
|
|
|
IICRC
INSPECTION
Home Inspection
Restoration Services
Exterior & Structure
Our inspection of the Exterior
grounds includes the surface drainage,
grading, some fencing, gates, sidewalks,
patios, driveways, and retaining walls
adjacent to the structure. The inspection of
the exterior of the building includes the
cladding, trim, eaves, fascias, decks,
porches, downspouts, railings, doors,
windows and flashings.
Roof Components
The inspection of the roof system includes a
visual examination of the surface materials,
connections, penetrations and roof drainage
systems. We examine the roofing material for
damage and deterioration. We examine the
roof system for possible leaks, damage and
conditions that suggest limited remaining
service life. We may offer opinions
concerning repair and/or replacement if
warranted. All roofmg systems require annual
maintenance. Failure to perform routine
maintenance will usually result in leaks and
accelerated deterioration of the roof
covering and flashings. When provided, our
estimates of the roofs life expectancy are
based on the assumption that the roof will
be properly maintained during that period.
We suggest that an annual inspection of the
Attic area be performed.
Plumbing System
Our Inspection of the plumbing system
includes a visual examination of the exposed
portions of the domestic water supply, drain
waste, vent, gas lines, faucets, fixtures,
valves, drains, traps, exposed pipes and
fittings. These items are examined for
proper function, excessive or unusual wear,
leakage and general state of repair. The
hidden nature of piping prevents inspection
of every pipe and joint connection,
especially in walls, floors and ceiling
voids. A sewer lateral test is necessary to
determine the condition of the underground
sewer lines. This type of test is beyond the
scope of this inspection. Our review of the
plumbing system does not include landscape
irrigation systems, water wells, on site
and/or private water supply systems, off
site community water supply systems, or
private (septic) waste disposal systems
unless specifically noted.Our inspection of
the water heater includes a visual
examination of the accessible portions of
the tank, gas, electrical and/or water
connections, venting and safety valves.
These items are examined for proper
function, excessive or unusual wear, leakage
and general state of repair.
Interior Our
inspection of the Interior includes a visual
inspection of the readily accessible
portions of the walls, ceilings, floors,
doors, cabinetry, countertops, steps,
stairways, balconies and railings. Please
note that a representative sample of the
accessible windows and electrical
receptacles are inspected. These features
are examined for proper function, excessive
wear and general state of repair. In some
cases, all or portions of these components
may not be visible because of furnishings
and personal items. In these cases some of
the items may not be inspected. The
condition of walls behind wall coverings,
paneling and furnishings cannot be judged.
Only the general condition of visible
portions of floors is included in this
inspection. As a general rule, cosmetic
deficiencies are considered normal wear and
tear and are not reported. Determining the
source of odors or like conditions is not a
part of this inspection. Floor covering
damage or stains may be hidden by furniture.
The condition of floors under flying floor
coverings is not inspected. Determining the
condition of insulated glass windows is not
always possible due to temperature, weather
and lighting conditions. Check with owners
for further information. All fireplaces
should be cleaned and inspected on a regular
basis to make sure that no cracks have
developed. Large fires in the firebox can
overheat the firebox and flue liners,
sometimes resulting in internal damage.
Kitchen
Inspection of standalone refrigerators,
freezers and built-in icemakers are outside
the scope of the inspection. No opinion is
offered as to the adequacy of dishwasher
operation. Ovens, self or continuous
cleaning operations, cooking functions,
clocks, timing devices, lights and
thermostat accuracy are not tested during
this inspection. Appliances are not moved
during the inspection to inspect below or
behind them. Portable dishwashers are not
inspected, as they require connection to
facilitate testing and are sometimes not
left with the home.
Bathrooms Our
inspection of the bathrooms included a
visual examination of the readily accessible
portions of the floors, walls, ceilings,
cabinets, countertops and plumbing fixtures.
Bathrooms are inspected for water drainage,
damage, deterioration to floor and walls,
proper function of components, active
leakage, unusual wear and general state of
repair. Bathroom fixtures are run
simultaneously to check for adequate water
flow and pressure. Fixtures are tested using
normal operating controls. Vent fans and
their ductwork are tested for their proper
operation and examined where visible. Shower
pans are visually checked for leakage, but
leaks often do not show except when the
shower is in actual use. Determining whether
shower pans, tub/shower surrounds are
watertight is beyond the scope of this
inspection. It is very important to maintain
all grout and caulking in the bath areas.
Very or imperfections can allow water to get
into the wall or floor areas and cause
damage. Proper ongoing maintenance will be
requir ed in the future.
Electric Our
examination of the electrical system
includes a visual examination of the exposed
and accessible branch circuits, wiring,
service panel, over current protection
devices, lighting fixtures, switches, and
receptacles. Service equipment, proper
grounding, wiring methods and bonding are
focal points. We inspect for adverse
conditions such as lack of grounding and
bonding, over-fusing, exposed wiring,
open-air wire splices, reverse polarity and
defective GFCI's. The hidden nature of the
electrical wiring prevents inspection of
every length of wire or their connections.
Telephone, video, cable, audio, security
systems and other low voltage systems were
not included in this inspection unless
specifically noted. We recommend you have
the seller or a specialist demonstrate the
serviceability or locations of these systems
to you if necessary. Any electrical repairs
attempted by anyone other than a licensed
electrician should be approached with
caution. The power to the entire house
should be turned off prior to beginning any
repair efforts, no matter how trivial the
repair may seem. Aluminum wiring requires
periodic inspection and maintenance by a
licensed electrician. Operation of time
clock motors is not verified. Inoperative
light fixtures often lack bulbs or have dead
bulbs installed. Light bulbs are not changed
during the inspection, due to time
constraints. Smoke Alarms should be
installed within 15 feet of all Bedroom
doors and in Bedrooms. These units should be
tested monthly
Heating Our
examination of the heating system includes a
visual examination of the exposed and
accessible heating equipment, thermostat,
safety controls, venting and the means of
air distribution. Our inspection of the
heating system includes activating the
heating system via the thermostat and a
visual examination of the accessible
components listed below. These items are
examined for proper function, excessive or
unusual wear and general state of repair.
Heat exchangers are inaccessible by design,
and are not part of the ASHI standards of
practice. They must be completely removed
from the furnace to be fully evaluated. Our
inspection does not include disassembly of
the furnace. The inspector cannot light
pilot lights due to the liability. The
inspector does not test safety devices. To
obtain maximum efficiency and reliability
from your heating system, we recommend
annual servicing and inspections by a
qualified heating specialist. Determining
the condition of oil tanks, whether exposed
or buried, is beyond the scope of this
inspection. Leaking oil tanks represent an
environmental hazard, which is sometimes a
costly condition to address.
Air Conditioning
This is a visual inspection limited
in scope by (but not restricted to) the
following conditions: - Window and/or wall
mounted air conditioning units are not
inspected. - The cooling supply adequacy or
distribution balance are not inspected. -
Pressure tests on coolant systems are not
within the scope of this inspection;
therefore no representation is made
regarding coolant charge or line integrity.
- Judgment of system efficiency or capacity
is not within the scope of this inspection.
- Cooling systems are not dismantled in any
way. Secured access covers are not removed.
- The interior components of evaporators,
condensers and heat pumps are not viewed. -
The interior conditions of cooling
components are not evaluated. - The presence
of leaking refrigerant lines, heat pump oil,
etc., is outside the scope of this
inspection.

|
|